AD/AA-5/8 Amdt 1 - Control Cables and Pulleys - Inspection (Cth)
Federal Register of Legislation
Full text
Select any passage to save a personal note with optional tags.
COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY
SCHEDULE OF AIRWORTHINESS DIRECTIVES
Gulfstream (Grumman American/ American Aviation) AA-5 Series Aeroplanes
AD/AA-5/8
Amdt 1
Control Cables and Pulleys - Inspection 10/74
Applicability: All model AA-5 with S/Nos. AA5-0001 to AA5-0209.
Requirement: Thoroughly clean and inspect all rudder, aileron and elevator cables as per Grumman American SB No. 127A.
Note: To adequately inspect the cables it will be necessary to actuate the controls to the full deflection to expose the complete cable pulley contact area for examination.
Compliance: Within 100 hours' time in service after 29 November 1974 and thereafter at intervals not exceeding 100 hours' time in service.