COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY SCHEDULE OF AIRWORTHINESS DIRECTIVES
Embraer EMB-110 (Bandeirante) Series Aeroplanes
AD/EMB-110/51 Generator Control Unit Overvoltage Protection Circuit
Applicability: This Directive is applicable to all EMB-110 Bandeirante aircraft.
3/96 DM
Requirement: 1. Perform a functional test of both generator control unit (GCU) overvoltage protection circuits in accordance with Embraer Service Bulletin SB 110-24-0037 dated 6 November 1995.
2. Replace the GCU with a serviceable unit.
Note: CTA (Brazil) AD 95-11-02R1 Amdt 39-754 refers.
Compliance: For Requirement 1 - Within 200 hours time in service or two calendar months, whichever occurs first, after 17 January 1996 and thereafter at intervals not exceeding 600 hours time in service.
For Requirement 2 - Before further flight, if the GCU fails the Requirement 1 functional test.
Background: Embraer has advised of instances concerning malfunction of voltage control and GCU overvoltage protection circuits. The reported malfunctions may cause damage to the electrical and electronic systems of the aircraft, including complete loss of generated power. Actions specified by this Directive are designed to provide early detection of malfunctioning circuitry.
We try to embed the page this law was scraped from. If the site blocks framing, you still get the link and a local excerpt.
Last checked with source on —
Checking whether the official page can be embedded…
Plain-English simplify of this law: a short summary, key points, and both sides of the argument. Generated on first view via Replicate, then cached. Vote on what helps your study.
No study brief is cached for this law yet. Sign up to generate a plain-English brief.
Sign up to generate