Federal Register of Legislation
AIRWORTHINESS DIRECTIVE For the reasons set out in the background section, the CASA delegate whose signature appears below issues the following Airworthiness Directive (AD) under subregulation 39.001(1) of CASR 1998. The AD requires that the action set out in the requirement section (being action that the delegate considers necessary to correct the unsafe condition) be taken in relation to the aircraft or aeronautical product mentioned in the applicability section: (a) in the circumstances mentioned in the requirement section; and (b) in accordance with the instructions set out in the requirement section; and (c) at the time mentioned in the compliance section.
Fokker F50 (F27 Mk 50) Series Aeroplanes AD/F50/95 Passenger Service Units 9/2006
Applicability: F27 Mark 050 and 0502 aeroplanes equipped with Honeywell International (Grimes Aerospace) Passenger Service Units (PSU) part number (P/N) 10-1178-XX. Requirement: 1. Inspect the affected PSU (P/N 10-1178-XX series) panel interface connectors in accordance with Section 3 - Accomplishment Instructions of Fokker Service Bulletin SBF50-25-061 dated 31 March 2006 or later EASA approved revision. 2. If, as a result of the Requirement 1 inspection, any discrepancies are found, rectify the discrepancy in accordance with Section 3 - Accomplishment Instructions of SBF50-25-061 or later EASA approved revision. Note: CAA-NL AD NL-2006-008 (EASA Approval 2006-0193) refers. Compliance: For Requirement 1 - Within 36 months after the effective date of this Directive. For Requirement 2 - Before further flight after the Requirement 1 inspection. This Airworthiness Directive becomes effective on 31 August 2006. Background: The Netherlands Civil Aviation Authority (CAA-NL) has advised that recently, a Fokker 100 (F28 Mark 0100) operator noted that the electrical connectors of the PSUs did not lock properly during installation in the aircraft. Investigation revealed that the lack of locking is caused by the tolerance in thickness of the gaskets (seals) inside the PSU connectors. This condition, if not corrected, may cause the connector to overheat, leading to electrical arcing and subsequent failure of the PSU Panels. In such instances, smoke is likely to be emitted. To rectify and prevent this occurring, the PSU manufacturer has narrowed the tolerances of the gaskets.
We try to embed the page this law was scraped from. If the site blocks framing, you still get the link and a local excerpt.
Last checked with source on —
Checking whether the official page can be embedded…
Plain-English simplify of this law: a short summary, key points, and both sides of the argument. Generated on first view via Replicate, then cached. Vote on what helps your study.
No study brief is cached for this law yet. Sign up to generate a plain-English brief.
Sign up to generate