AIRWORTHINESS DIRECTIVE On the commencement date specified below, and for the reasons set out in the background section, the CASA delegate whose signature appears below repeals Airworthiness Directive (AD) AD/GA8/9 and issues the following AD under subregulation 39.001 (1) of CASR 1998 and subsection 33 (3) of the Acts Interpretation Act 1901. The AD requires that the action set out in the requirement section (being action that the delegate considers necessary to correct an unsafe condition) be taken in relation to the aircraft or aeronautical product mentioned in the applicability section: (a) in the circumstances mentioned in the requirement section; and (b) in accordance with the instructions set out in the requirement section; and (c) at the time mentioned in the compliance section.
GippsAero GA8 Series Aeroplanes AD/GA8/9 Amdt 1 Wing Strut and Wing Strut 11/2018 Fittings - Inspection and Replacement
Applicability: All models of GippsAero GA8 and GA8-TC 320 aeroplanes. Requirement: 1. (a) Inspect the aeroplane for GippsAero Part Numbers GA8‑570026-035 Strut, GA8-570026-029 Strut Fitting Fuselage End, GA8‑570026-031 Strut Fitting Wing End, GA8-571022-105 Forward Strut Fitting RH, GA8-571022-106 Forward Strut Fitting LH, GA8-571022-107 Aft Strut Fitting LH, GA8-571022-108 Aft Strut Fitting RH and determine the serial number of each of these parts. (b) If the inspection identifies any part has a serial number listed in the applicability section of GippsAero Service Bulletin SB-GA8-2017-174 Issue 2 (the SB) as in force at the date of commencement of this AD, carry out a general visual inspection of the Wing Strut and Strut Fittings (the affected parts) for evidence of cracks, corrosion and damage in accordance with the requirements of the SB. 2. Report the results of all inspections including nil findings to: (a) CASA via its Defect Reporting Service, together with aircraft total time in service and current operational utilisation, and (b) GippsAero. 3. Replace any affected parts listed in Parts D and E of Table 3 of the SB. Note 1: The affected parts referenced in Requirement 3 are those with the serial numbers in Requirement 1(b). Note 2: Any non-destructive inspection methods other than the visual inspection detailed in the SB must be approved by CASA in writing as an alternative method of compliance. Compliance: 1. Carry out the inspections in accordance with Table 3 of the SB. Note 3: For areas where paint has been removed for inspection or found to be damaged, restore the surface protection in accordance with the SB. 2. Provide the reports within 24 hours of completion of any inspection required by Requirement 1.
We try to embed the page this law was scraped from. If the site blocks framing, you still get the link and a local excerpt.
Last checked with source on —
Checking whether the official page can be embedded…
Plain-English simplify of this law: a short summary, key points, and both sides of the argument. Generated on first view via Replicate, then cached. Vote on what helps your study.
No study brief is cached for this law yet. Sign up to generate a plain-English brief.
Sign up to generate